1250 KVA PERKINS NEWAGE DIESEL GENERATOR
Eagle Generators Ltd will arrange transport including shipping, call on Call now on 0121 454 4824 or email us at enquiries@dieselgenerators.com for a quote or to discuss in further detail.
|
|
| KVA : | 1250 |
| Engine Type : | Perkins 4012-46TWG2A |
| Volts : | 400 / 230 v |
| Cycles Hz : | 50 |
| R.P.M. : | 1500 |
| Fuel Consumption : | 264 Litre per hour |
| Price & Options |
| OPEN SETS | Additional Cost for | ||||
|---|---|---|---|---|---|
|
Manual Start |
Auto Start |
ATS Panel |
Acoustic Enclosure |
CE CERT (EU Only) |
|
|
Manual Auto |
ATS | ||||
| P.O.A. | P.O.A. | P.O.A. | P.O.A. | P.O.A. | P.O.A. |
All prices are in Sterling Pounds £ GBP Ex works UK
Prices are subject to VAT @15% (where applicable)
| Dimensions |
| CANOPIED | OPEN | ||||||
|---|---|---|---|---|---|---|---|
| Length (cm) | Width (cm) | Height (cm) | Weight (kg) | Length (cm) | Width (cm) | Height (cm) | Weight (kg) |
| - | - | - | - | 473 | 178 | 245 | 8,900 |
All dimensions and weights are approximate and should not be used for installation
Canopy height includes silencer
| Generating Set |
- Set Mounted Tropical Duty Radiator
- Engine Driven Cooling Fan with Protection Guard
- Radiator Stone Guard
- Fuel, Lubricating Oil and Air Filters with Restriction Indicators
- Electronic governing at 1500/1800 RPM in accordance with BS5514A1
- 24 Volt electric start with charging alternator
- Protection Switches for
- Low oil pressure
- High Engine Temprature
- Low coolant level
- Wiring to Control Panel
- Open channel baseframe (8 hour capacity basefuel tank with 4006C-23 Models), steel wire braded fuel lines terminated to base
- Anti vibration mountings supplied loose
- Set mounted Yuasa maintenance free lead acid battery with leads and terminals
- Exhaust flexible section(s) with connections
- S.L.S. exhaust Silencer(s) supplied loose
- Load and function tests
- Paint finish to our standard scheme
- Comprehensive user manual
| Keystart (Upto 1600 A) |
Alternator mounted profile control panel comprising -
- Ammeter per phase
- 1 x voltmeter
- Voltmeter selector switch
- Dual scale frequency/RPM indicator
- Hour counter
- 3 pole MCB/MCCB in separate alternator mounted cubicle
- Deep Sea 701 keystart module
- Shutdown indicator for
- High Engine Temperature
- Low oil pressure
- Low coolant level
- Overspeed
- Oil Pressure Gauge
- Water temperature gauge
- Battery voltmeter
| Keystart (Above 1600 A) |
As above but with ACB mounted in a separate freestanding cubicle
| Autostart (Without MCCB) |
As keystart but comprising the following additions -
- Constant Potential barrety charger
- Battery charger On/Off pushbutton
- Deep Sea 521K autostart module in place of 701 module
- Off/Auto/Manual selector keyswitch
- Indicators for
- Power On
- Remote start present
- Charge Fail
- Common Alarm
- Fail to start
- Multi attempt to start programme
- Programmed timers for
- Delay on start
- Mains restoration
- Run on for engine cooling
- Crank period
- Protected Override
- Excluding MCCB
| ATS |
Wall mounted enclosure comprising -
- Motor operated MCCB's 1000 A to 1250 A
- Motor operated ACB's 1600 A and above
- Indicators for
- Mains available
- Mains on load
- Generator Available
- Generator on load
- Phase failure monitor
Amps are at PRP Rating
Images are only representative and do not display actual generating sets