<%@ Language=VBScript %> <% dim idioma idioma = Request.QueryString("lan") on error resume next err.clear idioma = CStr(CInt(idioma)) if err.number > 0 then idioma = Session("idioma") err.clear end if if CInt(idioma) <= 0 or CInt(idioma) > 6 then idioma = Session("idioma") end if Session("idioma") = idioma ' should we show used prices, check dim show_prices %>
 

DEUTZ OPEN SET (21-550 KVA) PRICE LIST

Deutz Open Set Range (400/230v) Liquid Cooled

New Generators - European Manufacture New Generators - Deutz   UCC
Click here to open the
XE.com Currency Converter
50Hz @ 1500 RPM (400 / 230 volt)
kVA Genset Model Eng Type Manual Remote Start Pre wired Genset ACP ACP ACP + LTS ACP + LTS LTS Panel
M4 ** P4 ** (No 4-p breaker included)
A4 **
(4-p breaker included)

B4 **
(No 4-p breaker included)
C4 **
(4-p breaker included)

D4 **
21AD021 **F3M2011€ 5,596€ 5,373€ 5,820€ 6,029€ 379
31AD031 **F4M2011€ 5,878€ 5,642€ 6,113€ 6,330€ 405
41AD041 **BF4M2011€ 6,643€ 6,377€ 6,909€ 7,150€ 441
61AD061 **BF4M2012€ 9,421€ 9,044€ 9,637€ 9,919€ 685
85AD085 **BF4M1013E€ 10,744€ 10,315€ 10,932€ 11,214€ 741
105AD105 **BF4M1013EC€ 11,762€ 11,292€ 11,644€ 11,675€ 11,796€ 12,773€ 1,271
130AD130 **BF4M1013FC€ 13,568€ 13,025€ 13,432€ 13,914€ 14,067€ 15,240€ 1,271
131AD131 **BF6M1013E€ 13,426€ 12,890€ 13,292€ 13,864€ 14,017€ 15,100€ 1,271
150AD150 **BF6M1013EC€ 15,105€ 14,501€ 14,954€ 15,598€ 15,799€ 16,806€ 1,288
200AD200 **BF6M1013FCP€ 19,007€ 18,246€ 18,816€ 19,783€ 20,085€ 21,435€ 1,347
250AD250 **TCD2013L06-4V€ 22,384€ 21,488€ 22,160€ 22,748€ 23,070€ 24,725€ 1,570
300AD300 **BF6M1015C€ 28,423€ 27,286€ 27,817€ 28,783€ 21,481€ 29,821€ 1,852
380AD380 **BF6M1015CP€ 33,656€ 32,310€ 32,998€ 33,964€ 34,375€ 35,861€ 1,852
430AD430 **BF8M1015C€ 36,797€ 35,325€ 36,026€ 37,073€ 37,516€ 39,005€ 1,852
450AD450 **BF8M1015C2€ 38,085€ 36,562€ 37,221€ 38,429€ 38,912€ 43,502€ 1,852
500AD500 **BF8M1015CP€ 42,779€ 41,068€ 41,868€ 43,157€ 43,721€ 45,250€ 2,577




DEUTZ OPEN SET (21-550 KVA) SPECIFICATIONS

Deutz Open Set Range (400/230v) Liquid Cooled

New Generators - European Manufacture New Generators - Deutz    
50Hz @ 1500 RPM (400 / 230 volt)
Genset Model Eng Type kVA/kW Amp Weight Dimensions
Prime  Standby  Approx. Kg (length x width * height)
AD 021** F3M2011 20.9/19.1 21.9/20 32 540 1400 x 660 x 1300
AD 031** F4M2011 30/24 32/25.6 45 640 1650 x 730 x 1200
AD 041** BF4M2011 40/32 42/33.6 60 700 1700 x 730 x 1200
AD 061** BF4M2012 60/48 65/52 90 1000 1880 x 930 x 1490
AD 085** BF4M1013E 85/65 92/74 140 1100 2050 x 930 x 1430
AD 105** BF4M1013EC 105/84 108/86 200 1320 2230 x 930 x 1620
AD 130** BF4M1013FC 130/104 143/114 200 1460 2500 x 1100 x 1500
AD 131** BF6M1013E 130/104 143/114 200 1460 2340 x 1020 x 1400
AD 150** BF6M1013EC 150/120 165/132 325 1620 2500 x 1030 x 1520
AD 200** BF6M1013FCP 200/160 220/176 325 1740 2510 x 1030 x 1520
AD 250** TCD2013L06-4V 250/200 274/219.2 400 2200 3000 x 1200 x 2500
AD 300** BF6M1015C 300/240 330/264 630 2940 2750 x 1400 x 2290
AD 380** BF6M1015CP 380/304 414/331 630 3260 2750 x 1400 x 2290
AD 430** BF8M1015C 430/344 477/382 630 3700 3000 x 1460 x 2470
AD 450** BF8M1015C2 450/360 495/396 630 3900 3000 x 1460 x 2470
AD 500** BF8M1015CP 500/400 550/440 800 3920 3000 x 1460 x 2470


Scope of Supply
  • Engine and alternator are assembled on a rigid monoblock with axle connection by flexible disc.
  • The monoblock is mounted on a steel chassis standing on anti-vibration mountings.
  • The chassis contains the fuel tank.
  • The start is electrical and includes a battery.
Manual/Remote Start Panel
  • The control panel is controlled by a standby module with automatic start in the event of a utility.
  • The module is equipped with a LCD screen to allow users to read information such as voltage, amperage, mains and genset frequency.
  • The module also protects the engine and alternator.
  • Working hours preheating system and battery charger are included.
Automatic Control Panel
  • The control panel is controlled by a standby module with automatic start in the event of a utility.
  • The module is equipped with a LCD screen to allow users to read information such as voltage, amperage, mains and genset frequency.
  • The module also protects the engine and alternator.
  • Working hours preheating system and battery charger are included.
  • LTS panel is motorised from 300 kVA.
 
 

DEUTZ OPEN SET (18 - 56 KVA) PRICE LIST

Deutz Open Set Range (230v) Liquid Cooled

New Generators - European Manufacture New Generators - Deutz   UCC
Click here to open the
XE.com Currency Converter
50Hz @ 1500 RPM (230 volt)
kVA Genset Model Eng Type Manual Remote Start Pre wired Genset ACP ACP ACP + LTS ACP + LTS LTS Panel
M4 ** P4 ** (No 4-p breaker included)
A4 **
(4-p breaker included)

B4 **
(No 4-p breaker included)
C4 **
(4-p breaker included)

D4 **
18AD018 **F3M2011€ 6,156€ 5,691€ 5,947€ 6,246€ 524
26AD026 **F4M2011€ 6,466€ 5,780€ 6,283€ 6,771€ 595
36AD036 **BF4M2011€ 7,307€ 6,643€ 7,368€ 8,145€ 846
56AD056 **BF4M2012€ 10,363€ 9,721€ 10,312€ 11,532€ 1,449




DEUTZ OPEN SET (21-550 KVA) SPECIFICATIONS

Deutz Open Set Range (400/230v) Liquid Cooled

New Generators - European Manufacture New Generators - Deutz    
50Hz @ 1500 RPM (400 / 230 volt)
Genset Model Eng Type kVA/kW Amp Weight Dimensions
Prime  Standby  Approx. Kg (length x width * height)
AD018 **F3M201118.5/14.819.5/15.6905401400 x 660 x 1300
AD026 **F4M201126/2130/241206401650 x 730 x 1280
AD036 **BF4M201136/2940/321807201700 x 730 x 1200
AD056 **BF4M201256/4562/5028010001880 x 930 x 1490


Scope of Supply
  • Engine and alternator are assembled on a rigid monoblock with axle connection by flexible disc.
  • The monoblock is mounted on a steel chassis standing on anti-vibration mountings.
  • The chassis contains the fuel tank.
  • The start is electrical and includes a battery.
Manual/Remote Start Panel
  • The control panel is controlled by a standby module with automatic start in the event of a utility.
  • The module is equipped with a LCD screen to allow users to read information such as voltage, amperage, mains and genset frequency.
  • The module also protects the engine and alternator.
  • Working hours preheating system and battery charger are included.
 
 

DEUTZ ACOUSTIC SET (21-550 KVA) PRICE LIST

Deutz Acoustic Set Range (400/230v) Liquid Cooled

New Generators - European Manufacture New Generators - Deutz   UCC
Click here to open the
XE.com Currency Converter
50Hz @ 1500 RPM (400 / 230 volt)
kVA Genset Model Eng Type Manual Remote Start Pre wired Genset ACP ACP ACP + LTS ACP + LTS LTS Panel
M4 ** P4 ** (No 4-p breaker included)
A4 **
(4-p breaker included)

B4 **
(No 4-p breaker included)
C4 **
(4-p breaker included)

D4 **
21ID021 **F3M2011€ 7,609€ 7,305€ 7,753€ 7,962€ 379
31ID031 **F4M2011€ 7,811€ 7,499€ 7,973€ 8,186€ 405
41ID041 **BF4M2011€ 9,303€ 8,932€ 9,463€ 9,704€ 441
61ID061 **BF4M2012€ 11,970€ 11,492€ 12,085€ 12,367€ 685
85ID085 **BF4M1013E€ 13,125€ 12,600€ 13,217€ 13,499€ 741
105ID105 **BF4M1013EC€ 14,010€ 13,450€ 13,804€ 14,171€ 14,332€ 14,932€ 1,271
130ID130 **BF4M1013FC€ 16,426€ 15,769€ 16,177€ 16,657€ 16,811€ 17,985€ 1,271
131ID131 **BF6M1013E€ 16,264€ 15,614€ 16,017€ 16,589€ 16,750€ 17,826€ 1,271
150ID150 **BF6M1013EC€ 18,927€ 18,171€ 18,624€ 19,268€ 19,470€ 20,476€ 1,288
200ID200 **BF6M1013FCP€ 22,500€ 21,601€ 22,171€ 23,137€ 23,439€ 24,789€ 1,347
250ID250 **TCD2013L06-4V€ 25,846€ 24,812€ 25,484€ 26,072€ 26,394€ 28,049€ 1,570
300ID300 **BF6M1015C€ 32,207€ 30,919€ 31,446€ 32,412€ 32,819€ 34,098€ 1,852
380ID380 **BF6M1015CP€ 37,441€ 35,943€ 36,631€ 36,909€ 37,360€ 39,494€ 1,852
430ID430 **BF8M1015C€ 41,225€ 39,576€ 40,278€ 41,324€ 41,767€ 43,297€ 1,852
450ID450 **BF8M1015C2€ 43,440€ 41,703€ 42,362€ 43,570€ 44,053€ 46,227€ 1,852
500ID500 **BF8M1015CP€ 48,271€ 46,340€ 47,141€ 48,430€ 48,993€ 50,522€ 2,577




DEUTZ ACOUSTIC SET (21-550 KVA) SPECIFICATIONS

Deutz Acoustic Set Range (400/230v) Liquid Cooled

New Generators - European Manufacture New Generators - Deutz    
50Hz @ 1500 RPM (400 / 230 volt)
Genset Model Eng Type kVA/kW Amp Weight Dimensions
Prime  Standby  Approx. Kg (length x width * height)
ID021 **F3M201120.9/19.121.9/20329802000 x 950 x 1270
ID031 **F4M201130/2432/25.6459802000 x 950 x 1270
ID041 **BF4M201140/3242/33.66012002500 x 1100 x 1450
ID061 **BF4M201260/4865/529014402500 x 1100 x 1450
ID085 **BF4M1013E85/6592/7414017803000 x 1200 x 1500
ID105 **BF4M1013EC105/84108/8620019003000 x 1200 x 1500
ID130 **BF4M1013FC130/104143/11420021203000 x 1200 x 1500
ID131 **BF6M1013E130/104143/11420021203000 x 1200 x 1500
ID150 **BF6M1013EC150/120165/13232527003600 x 1350 x 2060
ID200 **BF6M1013FCP200/160220/17632530603600 x 1350 x 2060
ID250 **TCD2013L06-4V250/200274/219.240029003600 x 1350 x 2060
ID300 **BF6M1015C300/240330/26463043404200 x 1600 x 2040
ID380 **BF6M1015CP380/304414/33163046404200 x 1600 x 2040
ID430 **BF8M1015C430/344477/38263062904800 x 2000 x 2450
ID450 **BF8M1015C2450/360495/36063063404800 x 2000 x 2450
ID500 **BF8M1015CP500/400550/44080063804800 x 2000 x 2450


Scope of Supply
  • Engine and alternator are assembled on a rigid monoblock with axle connection by flexible disc.
  • The monoblock is mounted on a steel chassis standing on anti-vibration mountings.
  • The chassis contains the fuel tank.
  • The start is electrical and includes a battery.
Manual/Remote
  • The control panel is controlled by a manual/remote start module equipped with analogue gauges for voltage, amperage, frequency, fuel level and running hours.
  • The module is equipped with a LCD screen to allow users to read information such as voltage, amperage, mains and genset frequency.
  • 4-pole circuit breaker is standard up to 85kVA while 3-pole breaker is used for the rest.
Automatic Control Panel
  • The control panel is controlled by a standby module with automatic start in the event of a utility.
  • The module is equipped with a LCD screen to allow users to read information such as voltage, amperage, mains and genset frequency.
  • The module also protects the engine and alternator.
  • Working hours preheating system and battery charger are included.
  • LTS panel is motorised from 300 kVA
 
 

DEUTZ ACOUSTIC SET (18-56 KVA) PRICE LIST

Deutz Acoustic Set Range (230v) Liquid Cooled

New Generators - European Manufacture New Generators - Deutz   UCC
Click here to open the
XE.com Currency Converter
50Hz @ 1500 RPM (230 volt)
kVA Genset Model Eng Type Manual Remote Start Pre wired Genset ACP ACP ACP + LTS ACP + LTS LTS Panel
M4 ** P4 ** (No 4-p breaker included)
A4 **
(4-p breaker included)

B4 **
(No 4-p breaker included)
C4 **
(4-p breaker included)

D4 **
18ID018 **F3M2011€ 8,370€ 7,627€ 8,042€ 8,179€ 524
26ID026 **F4M2011€ 8,592€ 7,738€ 8,396€ 8,626€ 595
36ID036 **BF4M2011€ 10,323€ 9,213€ 10,040€ 10,698€ 846
56ID056 **BF4M2012€ 13,287€ 12,220€ 13,457€ 13,980€ 1,449




DEUTZ ACOUSTIC SET (21-550 KVA) SPECIFICATIONS

Deutz Acoustic Set Range (400/230v) Liquid Cooled

New Generators - European Manufacture New Generators - Deutz    
50Hz @ 1500 RPM (400 / 230 volt)
Genset Model Eng Type kVA/kW Amp Weight Dimensions
Prime  Standby  Approx. Kg (length x width * height)
ID018 **F3M201118.5/14.819.5/15.6909152000 x 950 x 1270
ID026 **F4M201126/2130/2412010252000 x 950 x 1270
ID036 **BF4M201136/2940/3218012402500 x 1100 x 1450
ID056 **BF4M201256/4562/5028014602500 x 1100 x 1450


Scope of Supply
  • Engine and alternator are assembled on a rigid monoblock with axle connection by flexible disc.
  • The monoblock is mounted on a steel chassis standing on anti-vibration mountings.
  • The chassis contains the fuel tank.
  • The start is electrical and includes a battery.
Manual/Remote
  • The control panel is controlled by a manual/remote start module equipped with analogue gauges for voltage, amperage, frequency, fuel level and running hours.
  • The module is equipped with a LCD screen to allow users to read information such as voltage, amperage, mains and genset frequency.
  • 4-pole circuit breaker is standard up to 85kVA while 3-pole breaker is used for the rest.